VS
07.94
1-92
 Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and StartāUp Guide/IAA/ā04.97 Edition
Table 1-8 Adaptation table for feed module 80/160 A
Servomotor
Current limit
1)
Current controller gain
1FT M[Nm] I[A] n
td
[RPM]
Contacts
I [A]
Contacts
Kp(I)1FT M
o
[Nm] I
o
[A] n
rated
[RPM]
2 3 4 5
I
max
[A]
6 7 8 9
K(I)
4101āVSK71
4101āVSN71
20.0
20.0
33.0
39.0
6000
8000
o
o
o
o
o
o
o
o
160.0
160.0
x
x
o
x
x
o
o
o
4.5
2.5
4102āVSG71
4102āVSK71
33.0
33.0
35.0
47.0
4000
6000
o
o
o
o
o
o
o
o
160.0
160.0
x
x
x
o
o
x
x
o
8.0
4.5
4104āVSG71
4104āVSK71
45.0
45.0
46.0
60.0
4000
6000
o
o
o
o
o
o
o
o
160.0
160.0
o
x
x
x
x
o
o
o
5.5
2.5
4106āVSG71 59.0 56.0 4000 o o o o 160.0 x o x o 4.5
5064āVAK71 4.5 8.0 6000 o o x x 41.6 x o x o 4.5
5066āVAG71
5066āVAK71
6.5
6.5
7.9
11.6
4000
6000
o
o
x
o
x
o
x
x
38.4
57.6
o
x
o
o
o
x
x
o
6.0
4.5
5071āVAK71 4.5 7.9 6000 o x x x 38.4 x o x o 4.5
5072āVAF71
5072āVAG71
5072āVAK71
10.0
10.0
10.0
9.1
12.0
17.5
3000
4000
6000
o
o
o
o
o
o
x
o
x
x
x
o
41.6
57.6
80.0
o
x
o
o
x
x
x
o
x
x
x
o
9.5
8.0
5.5
5073āVAG71
5073āVAK71
7.0
7.0
8.1
12.5
4000
6000
o
o
o
x
x
x
x
o
41.6
65.5
x
o
o
o
o
x
x
o
6.5
4.0
5074āVAC71
5074āVAF71
5074āVAG71
5074āVAK71
5074āVSG71
5074āVSK71
14.0
14.0
14.0
14.0
16.0
16.0
8.5
13.0
16.5
25.0
19.0
28.0
2000
3000
4000
6000
4000
6000
o
o
o
x
o
x
o
x
o
x
o
x
x
x
x
o
x
o
x
o
o
o
o
o
41.6
65.6
80.0
97.6
80.0
97.0
x
x
x
x
o
x
x
x
o
x
x
x
x
o
o
o
x
o
x
x
x
o
o
o
11.5
8.0
6.5
2.5
5.5
2.5
5076āVAC71
5076āVAF71
5076āVAG71
5076āVAK71
5076āVSG71
5076āVSK71
18.0
18.0
18.0
18.0
20.5
20.5
11.5
16.5
21.5
32.0
24.5
36.0
2000
3000
4000
6000
4000
6000
o
x
o
o
o
o
x
o
x
o
x
o
o
x
o
o
o
o
x
o
o
o
o
o
48.0
73.6
108.8
160.0
108.8
160.0
o
o
x
o
o
o
o
x
o
o
x
o
x
o
o
x
x
x
x
x
x
o
o
o
9.5
7.5
6.5
4.0
5.5
4.0
5100āVAF71
5100āVAG71
5100āVAK71
10.0
10.0
10.0
9.2
12.5
18.0
3000
4000
6000
x
x
o
x
x
o
o
x
x
x
o
o
46.4
62.4
80.0
x
x
o
x
o
o
o
o
x
x
x
o
8.0
6.5
4.0
5101āVAC71
5101āVAF71
5101āVAG71
5101āVAK71
15.0
15.0
15.0
15.0
9.4
14.5
17.5
26.5
2000
3000
4000
6000
o
o
o
x
o
x
o
o
x
x
x
o
x
o
o
o
41.6
65.6
80.0
136.0
o
x
x
o
o
o
o
o
x
o
x
x
x
x
o
o
9.5
6.5
4.5
4.0
5102āVAA71
5102āVAC71
5102āVAF71
5102āVAG71
5102āVSF71
5102āVSG71
27.0
27.0
27.0
27.0
34.0
34.0
9.9
16.5
25.0
31.5
31.5
39.5
1200
2000
3000
4000
3000
4000
x
o
o
o
o
o
x
o
x
o
x
o
o
x
o
o
o
o
x
o
o
o
o
o
46.4
80.0
108.8
160.0
108.8
160.0
x
o
o
o
x
x
x
o
x
x
o
o
x
x
x
x
x
x
x
x
o
o
o
o
11.5
9.5
5.5
5.5
4.5
4.5
5103āVAC71
5103āVAF71
5103āVAG71
19.0
19.0
19.0
12.0
17.5
23.0
2000
3000
4000
o
o
o
o
o
x
o
x
o
x
o
o
57.6
80.0
108.8
x
o
x
x
o
o
o
o
x
x
x
o
8.0
6.0
4.5
1)The specified value is the maximum permisisble current of the particular power module ā motor combination. It may be
necessary to reduce the specified value depending on the driven mechanical system.
1.2 Current controller settings
Feed modules
(VS)
03.96