Commissioning
4.4 Setting up a STEP 7 project
Connecting the SIMODRIVE 611U to the Technology CPU
26 Product Information, 03/2008, A5E00272066-05
Note
Alternatively, you can also run S7T Config without starting the Technology Objects
Management. To do this, select the object Technology objects in the folder Technology of
theTechnology CPU and start the S7T Config using the menu command Tools >
Configure technology. This procedure is particularly useful when no new technology
objects are to be created and consequently no technology data blocks need to be
created.
In S7T Config, open the Axes folder:
Figure 4-14 Inserting an axis
The following window opens after double clicking on Insert axis :
Figure 4-15 1st window of the axis configuration