Commissioning
4.4 Setting up a STEP 7 project
Connecting the SIMODRIVE 611U to the Technology CPU
Product Information, 03/2008, A5E00272066-05
51
4.4.4 "Measuring" function
Description
You can use the "measuring" function to acquire the actual position of an axis at any time. A
typical application is the acquisition of a print mark for the purpose of synchronizing the axis
to this mark.
Hardware configuration
The measuring input must be connected to the fast input I0.x. The input is isolated. This
enables more than one input to be switched in parallel, whereby the reference potential of
the 24 V supply of the measuring input (for example, from the network supply) must also be
wired.
9'&
//
0
&387'3
352),%86'3
6,02'5,9(8
%(52
(QFRGHUV
,QSXWWHUPLQDO
,[
5HIHUHQFHSRWHQWLDO
WHUPLQDO
Figure 4-34 Measuring