Commissioning
4.5 Drive configuration for SIMODRIVE 611U
Connecting the SIMODRIVE 611U to the Technology CPU
Product Information, 03/2008, A5E00272066-05
67
ā— You can select an external encoder in the Direct measuring system/encoder window. This
encoder can only be measured on a double-axis module via the measuring input for Axis
B. As a result, Axis B is no longer available for controlling an axis.
If you use the direct measuring system, you must select a PROFIBUS message frame
that contains a second encoder. In the technology CPU, you can assign this encoder for
the position control or create an external encoder that accesses this actual value.
Figure 4-49 Direct measuring system/encoder