Expert functions
5.8 Activating a brake
Connecting the SIMODRIVE 611U to the Technology CPU
Product Information, 03/2008, A5E00272066-05
83
Allocating the brake activation function to the digital output
In the expert list of the universal SIMODRIVE 611, each digital output has its own parameter.
Enter function value 35 in the parameter to which the digital output used in your application
is assigned. You can also invert the digital output via the bit mask in parameter P0699.
P0680 Alarm function - output terminal O0.x
P0681 Alarm function - output terminal O1.x
P0682 Alarm function - output terminal O2.x
P0683 Alarm function - output terminal O3.x
P0684 Alarm function - output terminal O4
P0685 Alarm function - output terminal O5
P0686 Alarm function - output terminal O6
P0687 Alarm function - output terminal O7
P0688 Alarm function - output terminal O8
P0689 Alarm function - output terminal O9
P0690 Alarm function - output terminal O10
P0691 Alarm function - output terminal O11
P0699 Inverting the output terminal signals
Example
Use output O3.A to activate the brake. Enter function value 35 in parameter P683.
0RWRUZLWK
PRWRUKROGLQJ
EUDNH
5HOD\V
WRFRQWUROWKH
PRWRUKROGLQJ
EUDNH
7HUP3
7HUP0
2XWSXW
2$
24 V
0 V
M
3 ~
6,02'5,9(XQLYHUVDO