Expert functions
5.8 Activating a brake
Connecting the SIMODRIVE 611U to the Technology CPU
86 Product Information, 03/2008, A5E00272066-05
Select the required response by the axis to axis errors with an error response
"RELEASE_DISABLE".
Ramp stop (OFF1):
Braking takes place at the drive's ramp function encoder ramp. When the speed threshold is
reached, the holding brake is enabled which disables the pulse enable once the brake
closing time has elapsed.
2))
6SHHGVHWSRLQW
$FWXDOVSHHG
n
+ROGLQJEUDNH
6ZLWFKLQJ2Q,QKLELWHG
%UDNHFORVLQJWLPH
+ROGLQJEUDNH
RSHQ
t
t
t
t
t