SINAMICS Integrated type
The following selection options are available for SIMOTION D445/D445‑1/D455‑2:
SINAMICS S120 Integrated
SINAMICS SM150 Integrated for applications with medium-voltage converters
A separate SIMOTION D firmware is available for each of the two versions.
Version of the SINAMICS Integrated
Depending on the selected SIMOTION version, several versions are available for the
SINAMICS Integrated. Please note that a separate SIMOTION D firmware is available for each
version of the SINAMICS Integrated.
Configuring the PROFINET interface
After you have acknowledged the "Insert SIMOTION Device" dialog with "OK", the "Properties
- Ethernet Interface" dialog box opens in the case of a D4x5‑2 DP/PN.
If you are using the PROFINET interface, set the interface properties in the "Properties -
Ethernet Interface" dialog box.
To this end, proceed as follows:
1. Click the "New" button.
The "New Subnet Industrial Ethernet" dialog box opens. Rename the new subnet, or accept
the default name by clicking "OK".
2. Select the new Ethernet subnet which is now displayed in the "Properties - Ethernet
Interface" dialog box.
3. Enter the required addresses in the "IP address" and "Subnet mask" fields of the "Properties
- Ethernet Interface" dialog box. Change to the "Network node" field and define whether
you are going to use a router and, if yes, enter the router address. Confirm with "OK".
Result
If you have not yet configured a PG/PC in your project, you can select the interface for the PG/
PC connection now.
6.2.2 Configuring the PROFIBUS PG/PC interface
Requirements
The following requirements must be satisfied in order to configure the PG/PC interface:
You have completed the "Insert SIMOTION Device" dialog box with "OK".
A PG/PC has not yet been configured in the project.
If these requirements have been satisfied, you can configure the interface for the PG/PC
connection in the "Interface Selection ‑ D4x5" dialog box.
Parameter assignment / addressing
6.2 Creating a project and configuring the communication
SIMOTION D4x5-2
126 Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5-2 and is the answer not in the manual?

Siemens SIMOTION D4x5-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5-2
CategoryControl Unit
LanguageEnglish

Related product manuals