Installing/mounting
4.3 Mounting the Power Modules
PM250 Power Module
24 Hardware Installation Manual, 01/2016, A5E36265179B-AA
Depth with Control Unit and Operator Panel (mm)
CU230P-2
CU240B/E-2
CU250S-2
with Control Unit:
With Control Unit and blanking cover / BOP-2:
With Control Unit and IOP:
+ 59
+ 70
+ 81
+ 41
+ 52
+ 63
+ 62
+ 73
+ 84
Table 4- 2 Drilling dimensions, cooling clearances and fixing
Frame size
Drilling dimensions (mm)
Cooling air clearances (mm)
Mounting
b
h
c
Top
Bottom
Front
Screws/torque
(Nm)
FSC without/with filter
167
323
6
125
125
65
4 x M5 / 3.0
FSD without filter
235
325
11
300
300
65
4 x M6 / 6.0
FSD with filter
235
419
11
300
300
65
4 x M6 / 6.0
FSE without filter
235
405
11
300
300
65
4 x M6 / 10
FSE with filter
235
541
11
300
300
65
4 x M6 / 10
FSF without filter
300
598
11
350
350
65
4 x M8 / 13
FSF with filter
300
898
11
350
350
65
4 x M8 / 13