Technical specifications
7.4 Power-dependent data
PM250 Power Module
60 Hardware Installation Manual, 01/2016, A5E36265179B-AA
7.4.1
Current derating depending on the pulse frequency
Article number
6SL3225-…
LO base
load
power
LO baseload output current [A] at a pulse frequency of…
4 kHz
6 kHz
8 kHz
10 kHz
12 kHz
14 kHz
16 kHz
-0BE25-5AA0
7.5
18.0
12.5
11.9
10.6
9.20
7.90
6.60
-0BE27-5AA0 11 25.0 18.1 17.1 15.2 13.3 11.4 9.50
-0BE31-1AA0
15
32.0
24.7
23.4
20.8
18.2
15.6
12.8
-0BE31-5AA0
18.5
38.0
32.3
26.6
22.8
19.0
17.1
15.2
-0BE31-8AA0
22
45.0
38.3
31.5
27.0
22.5
20.3
18.0
-0BE32-2AA0
30
60.0
51.0
42.0
36.0
30.0
27.0
24.0
-0BE33-0AA0
37
75.0
63.8
52.5
45.0
37.5
33.8
30.0
-0BE33-7AA0
45
90.0
76.5
63.0
54.0
45.0
40.5
36.0
-0BE34-5AA0
55
110
93.5
77.0
--
--
--
--
-0BE35-5AA0
75
145
123
102
--
--
--
--
-0BE37-5AA0
90
178
151
125
--
--
--
--

Table of Contents