EasyManua.ls Logo

Siemens Sinamics PM250 - Sine-Wave Filter

Siemens Sinamics PM250
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spare parts and accessories
8.2 Optional accessories
PM250 Power Module
78 Hardware Installation Manual, 01/2016, A5E36265179B-AA
8.2.4
Sine-wave filter
The sine-wave filter at the inverter output limits the voltage rate-of-rise and the peak voltages
at the motor winding. The maximum permissible length of motor feeder cables is increased
to 300 m.
The following applies when using a sine-wave filter:
Operation is only permissible with pulse frequencies from 4 kHz to 8 kHz.
From 110 kW power rating of the Power Modules (according to the rating plate) only
4 kHz is permissible.
The inverter power is reduced by 5%.
The maximum output frequency of the inverter is 150 Hz at 380 V to 480 V.
Operation and commissioning may only be performed with the motor connected, as the
sine-wave filter is not no-load proof.
An output reactor is superfluous.
Dimensions and drilling patterns
Image 8-8 Dimensions - footprint filter
Mounting position
Image 8-9 Mounting position - footprint filter

Table of Contents

Related product manuals