Technical specifications
7.4 Power-dependent data
PM250 Power Module
Hardware Installation Manual, 01/2016, A5E36265179B-AA
59
Table 7- 4 PM250, IP20, frame sizes E, 3 AC 380 V … 480 V
Article No. - with filter
LO base load power
LO base load input current
LO base load output current
37 kW
70 A
45 kW
84 A
HO base load power
HO base load input current
HO base load output current
30 kW
56 A
37 kW
70 A
Fuse according to IEC
Fuse according to UL
3NA3830
100 A, Class J
3NA3832
125 A, Class J
Required cooling air flow
Tightening torque for line and motor cables
Table 7- 5 PM250, IP20, frame sizes F, 3 AC 380 V … 480 V
Article No. - with filter
LO base load power
LO base load input current
LO base load output current
55 kW
102 A
75 kW
135 A
90 kW
166 A
HO base load power
HO base load input current
HO base load output current
45 kW
84 A
55 kW
102 A
75 kW
135 A
Fuse according to IEC
Fuse according to UL
3NA3836
160 A, Class J
3NA3140
200 A, Class J
3NA3144
250 A, Class J
Power loss 1.5 kW 2.0 kW 2.4 kW
Required cooling air flow 94 l/s 94 l/s 117 l/s
Tightening torque for line and motor cables