3.3 Cooling system test
3.3.1 Static pressure test
Fundamentals
Tests are performed according to IEC 61800-5-1 and DIN EN 805.
The drive cooling system is checked for leaks and pressure drop for one hour.
Test procedure
1. The cooling system is filled with coolant and the valves in the supply and return lines are
closed.
2. With the valves closed, pressure is increased to a test pressure of p
t
and is controlled for the
next 10 min.
3. After a total of 30 min, pressure p
1
is measured.
4. After a total of 60 min, pressure p
2
is measured.
3UHVVXUH
7HVW
SUHVVXUH
3W
3
3
PLQืPLQPLQPLQ
7LPH
3UHOLPLQDU\WHVW0DLQWHVW
Figure 3-1 Procedure for the pressure test
5. The pressure drop is calculated from measured values: Δp = p
1
- p
2
Result
The test is passed if the differential pressure is ≤ 0.4 bar and no leaks have occurred in the
cooling system.
Tests
3.3 Cooling system test
SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76
28 Reference Manual Rev.201902141427 SL150 wassergekühlt