Start-Up
SINUMERIK 802S base line
4-49
Start-Up
MD Description
35400 Reciprocation speed
35410 Acceleration when reciprocating
35430 Start direction in reciprocation
35440 Reciprocation time for M3 direction
35450 Reciprocation time for M4 direction
Interface signals
“Switch gear“ 39032000 bit 3
“Reciprocation speed” 38032002 bit 5
“Reciprocation by PLC”38032002 Bit 4
“Setpoint direction CCW“ bit 7
“Setpoint direction CW” 38032002 bit 6
“Reciprocation mode” 39032002 bit 6
“Gear has been switched” 38032000 bit 3
4.7.4 Completing the Start-Up
After start-up of the control system by the machine manufacturer, the following
should be observed prior to delivery to the final customer:
1. Change the default password for access level 2 from ”EVENING” to your
own password.
If the machine manufacturer uses the password ”EVENING” for access
level 2 during the start-up work, the password must be changed.
Press the softkey Change passw.
Enter the new password and press OK to confirm.
Note the password in the Manufacturer Documentation.
2. Reset the access level.
To save the data which have been set during the start-up, an internal data
saving is required. To this aim, set access level 7 (final customer);
otherwise, access level 2 will also be saved.
Press the softkey Delete passw.
The access level will be reset.
3. Carry out internal data saving.
Press the softkey Save data.