9 Alarms 01.93
9.3 Alarm description
4039
Program RESET necessary
Explanation:
Remedy:
Measuring error
Program abort only possible by pressing the RESET key.
4040
Oversize
Explanation:
Remedy:
The set/actual difference is greater than the centre tolerance.
There is too much material at the measuring point.
Tool has been compensated for if R10 > 0.
Re-machining is possible.
4041
Undersize
Explanation:
Remedy:
The set/actual difference is less than the centre tolerance.
There is too little material at the measuring point.
Tool has been compensated for if R10 > 0.
Re-machining is not possible.
4042
Perm. dim. diff'ce exceeded
Explanation:
Remedy:
The set/actual difference is greater than R37.
•
Chipping of cutting edge
•
Too much wear in last cut, because hard spots have been
encountered in the workpiece.
No tool offset has been carried out.
Tool must be replaced.
4048
No active tool available
Explanation: The tool to be compensated is not available in tool management.
•
Tool life exceeded
•
Twin tool not available
9–12 © Siemens AG 1990 All Rights Reserved 6FC5197- AB70
SINUMERIK 840/850/880 (BN)