10 Lists 01.93
10.2 Result displays
Measurement result display for workpiece probe calibration
AUTOMATIC - CH1
Workpiece measurement: Measurement result Cycle 215
Input data
Measurement variant 23
Safe area 36
Lower limit 33
Probe No. 218
Data 217
Output data
Actual value Difference
Probe ball 200 201
Abscissa - direction 202 203
Abscissa +direction 204 205
Ordinate - direction 206 207
Ordinate +direction 208 209
Applicate - direction 210 211
Applicate +direction 212 213
Position abscissa 214
Position ordinate 216
Alarm No. 219
Measurement result display for workpiece measurement
AUTOMATIC - CH1
Workpiece measurement: Measurement result Cycle 215
Input data Output data
Diameter /width 1st axis 2nd axis
Set value 206 207 208
Actual value 209 210 211
Tolerance upper limit 200 201 202
Tolerance lower limit 203 204 205
Difference 212 213 214
Compensation value 50
Alarm No. 219
Measurement variant 23
Safe area 36
Perm. dim. diff'ce 37
D/ZO memory No. 216
Probe No. 218
Data 217
10–22 © Siemens AG 1990 All Rights Reserved 6FC5197- AB70
SINUMERIK 840/850/880 (BN)