1 Introduction 10.91
1.9.2 Logging via CP315 with the SINUMERIK 840/880
– Description of decimal place 5
R39=xx9xxxxx End of measurement result logging
– Description of decimal place 3
R39=xxxx0xxx Measuring point number from the PLC
R39=xxxx5xxx Measuring point number from R45
– Description of decimal place 2
R39=xxxxx0xx Transfer of part program for a form
R39=xxxxx1xx Transfer of workpiece-specific header data
R39=xxxxx2xx Transfer of measurement results
– Description of decimal place 1
R39=xxxxxx2x Do not mark the measurement result with a special character (base
line)
R39=xxxxxx3x Mark the measurement result with a special sign (base line)
R39=xxxxxx5x Space line (with frame)
R39=xxxxxx6x Page feed
– Description of decimal place 0
R39=xxxxxxx 0 Number of protocol lines of a measuring point
: or number of blanks
9
0 Output basic line only
1 Output basic line + supplementary line
2 Output basic line + 2 supplementary lines
• Control parameter R38
R38 is an 8-digit control parameter.
0 = Do not mark line
1 = Mark line with special character
1st supplementary line
.
.
8th supplementary line
R38=xxxxxxxx
Mark measurement result with special character (1st to 8th supplementary line).
Explanation: Special character = tolerance exceeded
• Transfer parameters for header data (R40 ... R45)
R39=xxxxy1xx y=0 or 5
1)
e.g. R40=7 ... 0 e.g. Part No.
e.g. R41=15 ... 0 e.g. Order No. (e.g. Digital places 8 ... 15
2)
)
e.g. R42=7 ... 0 e.g. Order No. (e.g. Digital places 0 ... 7
2)
)
e.g. R43=3 ... 0 e.g. Program No.
e.g. R44 not evaluated
e.g. R45 not evaluated
– Example showing header data
R39=11110100
R40=100.4711
R41=0
R42=100
R43=22
Header data must be output by the part program before the first measuring points are
measured.
_______
1)
y=0: Automatic assignment of measuring point number
y=5: Assignment by part programmer
2)
determined in the form description
1–36 © Siemens AG 1990 All Rights Reserved 6FC5197- AB70
SINUMERIK 840/850/880 (BN)