Procedure
1. The "Settings" window is open.
Press the "URLs>" softkey.
2. Press the "Edit" softkey and select the following settings:
Directory: Select the "User" entry in the "Directory" drop-down list.
Display home page: Select the "Overwrite here" check box.
RenderService: Select the "Overwrite here" check box.
URL web service: Select the "Overwrite here" check box.
Enter the following WebService URL, for example, for the MindSphere V3 Livesystem:
https://gateway.eu1.mindsphere.io/api/agentcom-mmmops/v3/ws11
Enter the required value in the "Transmit timeout ms" text box (default value is 200). For
MindSphere, a value of "20" is recommended, and select the "Overwrite here" check box.
Enter the required value in the "Timeout on receive in ms" text box (default value is 200).
For MindSphere, a value of "20" is recommended, and select the "Overwrite here" check
box.
3. Press "OK".
A syntax check is performed and the access data is saved.
4. To establish a connection from the customer network, you must adapt the proxy settings.
Press the "Proxys>" softkey.
The stored settings are displayed.
Installation/configuration
4.2 SINUMERIK control with SINUMERIK Operate - Setting the proxy
Manage MyMachines /Remote - installation in existing control environments