5.4.8.2 Diagnostics options during booting
Diagnostics options during booting
In the following cases, the diagnostics window is displayed and booting of the TCU is
interrupted:
When the <1 / F1> function is selected during booting
When a warning message is displayed
When a fault occurs
Note
You can select functions <1 / F1> to <8 / F8> mentioned below by tapping on the Panel.
Alternatively, you can do this via the corresponding function keys of a connected USB
keyboard.
Call diagnostics window by tapping on <1 / F1
7hin Client Bootloader
Boot Progress
BIOS Version
MAC Address
Hardware-ID
Network link
Boot from USB
IP Address
Netmask
DHCP Server
Boot Server
Image Metadata
Image Version
Linux Image (linux.bin)
Image Kind
Booting
<1/F1> protocol <2/F2> Readme_OSS <7/F7> continue <8/F8> reboot
V05.00.45.00
V15.00.00.00
08:06:00:F1:F7:F8
7.9.2.0
1000MB, full duplex
no device found
192.168.214.14
255.255.255.0
192.168.214.1
192.168.214.1
71 bytes
V05.00.46.00
3295436 bytes
from boot server
ready
Key / text Meaning
F1 protocol Display detailed information
F2 Readme_OSS Details of the Open Source licenses
F7 continue Continue booting of the TCU
F8 reboot Restart the TCU
Networking
5.4 Service and diagnostics
TCU 30.3
70 Manual, 09/2017, A5E40874197

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl TCU 30.3