7 Measuring in JOG Mode (SINUMERIK 880/880 GA2) 01.93
7.1.1 Operating and function sequence
The following applies when retracting the measuring probe:
The probe can only be retracted in the opposite direction to that of the measuring
direction.
All other axes, axis directions and rapid traverse are disabled.
When the retraction path has been completed it again becomes possible to move along
every axis and the basic display JOG appears.
The length of the retraction path depends on the
machine configuration.
(See information supplied by the machine tool
manufacturer).
If the measured value is not to be stored the function can be aborted with RESET or a mode
change. The dialog text "JOG-MEASUREMENT ABORTED" appears on the screen. In this
case retraction is not limited to a predefined distance, i.e. any axis can be traversed without
limitation.
7–8 ©
Siemens AG 1990 All Rights Reserved 6FC5197- AB70