9 Alarms 01.93
9.3 Alarm description
4025
Tool tip position wrong
Explanation:
Remedy:
The tool is to be measured in the X axis. The cycle
wants to position the Z axis, but this would result in a
collision with the measuring cube.
Tool cutting edge incorrectly positioned
Tool cutting edge correctly positioned
Probe cube
CP
Tool cutting edge
Z
X
Probe cube
Z
X
CP
Tool cutting edge
Position tool in X axis before cycle call with greater
positive value.
4026
Toolnose location 9 defined
Explanation:
Remedy:
Tool point direction 9 cannot be measured with measurement variant
”Automatic measuring” (R23 > 1).
Use measurement variant 1.