4.3.2 Transport and Storage Conditions
Components in original packaging 
The following specifications apply to components in transport packaging:
  Transport Storage
Standard / class EN 60721-3-2 EN 60721-3-1
Temperature range -20 ... + 60 °C -25 ... + 55 °C
Temperature change -40 °C/+30 °C and +70 °C/+15 °C 
*)
< 0.5 K / min (≙ 30 K / h) 
averaged over 5 minutes
Relative humidity 5 ... ~95% 10 ... 100 %
Permissible change of the rel‐
ative humidity
max. 0.1% / min (≙ 6% / h)
*)
A direct change between the specified temperatures in the air is assumed
Table 4-2 Transport values for PPU
Vibratory load:
● Operation (3M1)
● Package (1M2)
 
 
9 - 29 Hz: 0.3 mm; 29 - 200 Hz: 1g 
5 - 9 Hz: 3.5 mm, 9 - 200 Hz: 1 g
Shock load:
● Operation (3M1)
 
5 g, 30 ms
Product packaging 1M2
4.3.3 Operating Conditions
Note
Before commissioning components with display, remove the foil which is used to protect the 
components during transport. 
Climatic environmental conditions of  PPU 1740-1500 and PPU 1740-1900
Parameters Values 
Limit temperatures at 100% load 0 ... 40 °C (front)
0 ... 45 °C (rear)
Temperature change < 0.5 K / min (≙ 30 K / h) averaged over 5 minutes
Humidity Relative: 5 … 90 % 
Permissible change of the relative humidity max. 0.1% 
min (≙ 6% / h)
Application planning
4.3 Climatic and mechanical environmental conditions
PPU 1740
Equipment Manual, 01/2019, A5E47615272B AA  47