Mounting an NX10.3 / NX15.3 onto an Active Line Module
Procedure:
1. Remove the spacers from the NX.
2. Position the NX on the left-hand side of the Line Module. The mounting fixtures fit exactly in
the five cutouts on the NX.
3. Push the two units together.
4. Press down on the NX until it engages and is securely connected to the Line Module.
8.1.4 Dimension drawing
Dimension drawing
Figure 8-4 Dimensions NX10.3 / NX15.3
Connectable components
8.1 NX10.3 / NX15.3
PPU 1740