EasyManua.ls Logo

Siemens SIRIUS 3RW5 - Page 163

Siemens SIRIUS 3RW5
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.2 Data tables
SIRIUS 3RW5 Modbus communication module
Equipment Manual, 03/2020, A5E43676481002A/RS-AC/003
163
Register
Byte
Data format
Maximum pointer
Range of values
In steps of
3RW
Address
high /
low
50 /
52
1)
55 /
55-F
2)
0x901E
[36894]
high
Unsigned8
Minimum line frequency
0 100 Hz
0.5 Hz
-
r
low
Unsigned8
Maximum line frequency
0 100 Hz
0.5 Hz
-
r
0x901F
[36895]
high Unsigned32 Operating hours - motor current =
18...49.9% x Ie
0
4 294 967 295 s
1 s r r
0x9021
[36897]
high Unsigned32 Operating hours - motor current =
50...89.9% x Ie
0
4 294 967 295 s
1 s r r
0x9023
[36899]
high Unsigned32 Operating hours - motor current =
90...119.9% x Ie
0
4 294 967 295 s
1 s r r
0x9025
[36901]
high Unsigned32 Operating hours - motor current =
120...1000% x Ie
0
4 294 967 295 s
1 s r r
0x9027
[36903]
high Unsigned32 Operating hours - device 0
4 294 967 295 s
1 s r r
0x902B
[36907]
high Signed32 Starting current I max (rms) -20 000
20 000 A
0.01 A r r
0x902D
[36909]
high Signed32 Starting current I L1 max (rms) -20 000
20 000 A
0.01 A r r
0x902F
[36911]
high Signed32 Starting current I L2 max (rms) -20 000
20 000 A
0.01 A r r
0x9031
[36913]
high Signed32 Starting current I L3 max (rms) -20 000
20 000 A
0.01 A r r
0x9033
[36915]
high Unsigned16 Number of starts with ext. bypass 0 65 535 1 r r
3), 4)
1)
Supported by SIRIUS 3RW50 soft starter from firmware version V1.0 and 3RW52 from firmware version V2.0
2)
Supported by SIRIUS 3RW55 and 3RW55 Failsafe soft starters
3)
3RW55 soft starter from firmware version V2.0
4)
Not supported by SIRIUS 3RW55 Failsafe soft starter

Other manuals for Siemens SIRIUS 3RW5

Related product manuals