Performing basic parameterization
6.3 Drive axes
152 Getting Started, 12/2018, 6SL3097-5AG30-0BP0
Number
Designation
Description
p1120
Ramp-up time
Ramp-up/ramp-down time always refers to the time interval from motor standstill to the set
maximum speed (without using roundings).
p1121
Ramp-down time
p1135 OFF3 ramp-down
time
The OFF3 ramp-down time is effective from the maximum speed down to the motor
standstill.
Precondition
You have completely specified and configured the motor used in the device configuration
of the drive axis.
Note
This basic parameterization cannot be performed without having completed this full
configuration.
6.3.2.5
Optimization runs
"Drive axis > Parameters > Basic parameterization > Optimization runs"
Using the "Optimization run" function, you can calculate motor and controller data for motors
in the motor list as well as for non-listed motors.
Preconditions
You have completely specified and configured the motor used in the device configuration
of the drive axis.
Note
Specifying third-party (non-listed) motors
When third
-party motors are specified, the motor data must be manually entered (see
Chapter "
Inserting and specifying motors that are missing from the motor list (Page 89)").
Note
This basic parameterization cannot be performed without having completed this full
configuration.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals