Technical data
6
Note
Technical data a
pply for a rated input voltage, rated load and 25 °C ambient temperature if
nothing else is specified.
6.1
Input
6EP1332-1LB00
(24 V/2.5 A)
6EP1333-1LB00
(24 V/5 A)
6EP1334-1LB00
(24 V/10 A)
6EP1336-1LB00
(24 V/20 A)
Input
1-phase, AC
Rated voltage U
in rated
120/230 V
100 - 240 V
Voltage range
Remark
93 - 132 V/187 - 264 V
Setting via selector switch at the device
85 - 264 V AC
88 - 370 V DC
Switch-in/switch-off thresh-
old, typ.
72 V/61 V or
144 V/106 V
68 V/64 V or
136 V/106 V
82 V/71 V or
166 V/131 V
81 V/72 V AC
112 V/65 V DC
Overvoltage strength
2.3 × U
in rated
, 1.3 ms
Line failure buffering at
I
out rated
, min.
20 ms 20 ms 20 ms 20 ms
Power failure buffering
at 93/187 V
at 85/170 V
Rated line frequency
50 - 60 Hz
Line frequency range
47 - 63 Hz
Input current / at rated value
of input voltage 120 V
1.1 A 2.1 A 4.1 A 5.55 A
Input current/at rated value
of input voltage 230 V
0.65 A 1.15 A 2 A 2.35 A
Inrush current limiting
(25 °C), max.
27 A 32 A 65 A 45 A
I²t, max.
0.3 A
2
s
0.8 A
2
s
3.3 A
2
s
-
Duration of the switch-on
current limiting / at
25 °C/typical
3 ms 3 ms 3 ms -
Integrated input fuse T 2 A/250 V
(not accessible)
T 3.15 A/250 V
(not accessible)
T 6.3 A/250 V
(not accessible)
T 10 A/250 V
(not accessible)
Protection in the line feeder
cable (IEC 898)
Recommended min-
iature circuit-breaker:
from 3 A, characteris-
tic C
Recommended min-
iature circuit-breaker:
from 6 A, characteris-
tic C
Recommended min-
iature circuit-breaker:
from 10 A, character-
istic C
Recommended min-
iature circuit-breaker:
from 10 A, character-
istic C