2
DEVICE DESCRIPTION
10
SITRANS FX330
www.siemens.com/flow 08/2017 - A5E42667474-AA EN
Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection
box mounted above the flow sensor
box mounted above the flow sensorbox mounted above the flow sensor
box mounted above the flow sensor
Max. permissible product and ambient temperatures per temperature class in °C
Max. permissible product and ambient temperatures per temperature class in °F
Temperature class T6 T5 T4 T3 T2
T
amb
in °C 60 65 60 65 60 65 40 60 65 40 60 65
Nominal size
DN1525 80 65 100 100 135 135
1
200 200
1
165
1
240 200
1
165
1
DN4050 80 65 100 100 135 135
1
200 175
1
150
1
240 175
1
150
1
DN65100 80 65 100 100
1
135
1
130
1
200 150
1
130
1
235
1
150
1
130
1
DN150...300 75 65 100 100 135 135
1
200 185
1
155
1
240 185
1
155
1
1 Permanent service temperature of connecting cable and cable entry min. 80°C
Temperature class T6 T5 T4 T3 T2
T
amb
in °F 140 149 140 149 140 149 104 140 149 104 140 149
Nominal size
DN1525 176 149 212 212 275 275
1
392 392
1
329
1
464 392
1
329
1
DN4050 176 149 212 212 275 275
1
392 347
1
302
1
464 347
1
302
1
DN65100 176 149 212 212
1
275
1
266
1
392 302
1
266
1
455
1
302
1
266
1
DN150...300 167 149 212 212 275 275
1
392 365
1
311
1
464 365
1
311
1
1 Permanent service temperature of connecting cable and cable entry min. 176°F