Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection Maximum permissible product and ambient temperatures with signal converter or connection
Maximum permissible product and ambient temperatures with signal converter or connection
box mounted at side or underneath the flow sensor
box mounted at side or underneath the flow sensorbox mounted at side or underneath the flow sensor
box mounted at side or underneath the flow sensor
Max. permissible product and ambient temperatures per temperature class in °C
Max. permissible product and ambient temperatures per temperature class in °F
Temperature class T6 T5 T4 T3 T2
T
amb
in °C 60 65 60 65 60 65 40 60 65 40 60 65
Nominal size
DN15…25 85 65 100 100 135 135 200 200 200 1 240 240 240 1
DN40…50 80 65 100 100 135 135 200 200 200 1 240 240 240 1
DN65…100 85 65 100 100 135 135 1 200 200 1 200 1 240 240 1 240 1
DN150...300 80 65 100 100 135 135 200 200 200 1 240 240 240 1
1 Permanent service temperature of connecting cable and cable entry min. 80°C
Temperature class T6 T5 T4 T3 T2
T
amb
in °F 140 149 140 149 140 149 104 140 149 104 140 149
Nominal size
DN15…25 185 149 212 212 275 275 392 392 392 1 464 464 464 1
DN40…50 176 149 212 212 275 275 392 392 392 1 464 464 464 1
DN65…100 185 149 212 212 275 275 1 392 392 1 392 1 464 464 1 464 1
DN150...300 176 149 212 212 275 275 392 392 392 1 464 464 464 1
1 Permanent service temperature of connecting cable and cable entry min. 176°F