SITRANS P DS III (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434626-03, 06/2013
35
Devices identified by this symbol may not be disposed of in the municipal waste
disposal services under observance of the Directive 2002/96/EC on waste electronic
and electrical equipment (WEEE).
They can be returned to the supplier within the EC or to a
locally approved disposal
service. Observe the specific regulations valid in your country.
Note
Special disposal required
The device includes components that require special disposal.
Dispose of the device properly and environmentally through a local waste disposal contractor.
Technical specifications
7.1
PROFIBUS PA and FOUNDATION
TM
Fieldbus
Span (continuously
adjustable) or measuring
range, max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive) and
max. test pressure (in
accordance with
DIN 16086) (max. 120 bar
for oxygen measurement)
Span Maximum
operating
pressure
Maximum
test
pressure
Measuring
range
Maximum
operating
pressure
Maximum
test pressure
0.01 … 1 bar g
(0.15 …
4 bar g
(58 psi g)
6 bar g
(87 psi g)
1 bar g
(14.5 psi g)
4 bar g
(58 psi g)
6 bar g
(87 psi g)
0.04 … 4 bar g
(0.58 …
7 bar g
(102 psi g)
10 bar g
(145 psi g)
4 bar g
(58 psi g)
7 bar g
(102 psi g)
10 bar g
(145 psi g)
0.16 …
16 bar g (2.3
21 bar g
(305 psi g)
32 bar g
(464 psi g)
16 bar g
(232 psi g)
21 bar g
(305 psi g)
32 bar g
(464 psi g)
0.63 … 63 bar
g (9.1 …
67 bar g
(972 psi g)
100 bar g
(1450 psi g)
63 bar g
(914 psi g)
67 bar g
(972 psi g)
100 bar g
(1450 psi g)
1.6 …
160 bar g (23
167 bar g
(2422 psi g)
250 bar g
(3626 psi g)
160 bar g
(2321 psi g)
167 bar g
(2422 psi g)
250 bar g
(3626 psi g)
4 … 400 bar g
(58 …
400 bar g
(5802 psi g)
600 bar g
(8702 psi g)
400 bar g
(5802 psi g)
400 bar g
(5802 psi g)
600 bar g
(8702 psi g)
7.0 ...
700 bar g
(102 ...
800 bar g
(11603 psi g)
800 bar g
(11603 psi g
)
700 bar g
(10153 psi g)
800 bar g
(11603 psi g)
800 bar g
(11603 psi g)