SITRANS P DS III (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434626-03, 06/2013
39
Rated conditions for gauge pressure and absolute pressure (from the gauge pressure series)
Observe the temperature class in hazardous areas.
Measuring cell with silicone oil
-40 … +85 °C (-40 … +185 °F)
Measuring cell with inert liquid -20 … +85 °C (-4 … +185 °F)
Display -30 … +85 °C (-22 … +185 °F)
-50 … +85 °C (-58 … +185 °F)
● Degree of protection in
IP65, IP68
● Degree of protection in
NEMA 4X
Electromagnetic compatibility
Interference emission and
In accordance with EN 61326 and NAMUR NE 21
Process medium conditions
● Process temperature
Measuring cell with silicone oil
-40 … +100 °C (-40 … +212 °F)
Measuring cell with inert liquid
-20 … +100 °C (-4 … +212 °F)
-20 … +60 °C (-4 … +140 °F)
Conditions of use for gauge pressure and absolute pressure with flush-mounted diaphragm
Observe the temperature class in explosive atmospheres.
● Measuring cell with silicone oil
-40 … +85 °C (-40 … +185 °F)
Measuring cell with inert liquid
-20 … +85 °C (-4 … +185 °F)
Measuring cell with Neobee
(FDA-compliant)
-10 … +85 °C (14 … 185 °F)
● Display
-30 … +85 °C (-22 … +185 °F)
● Storage temperature
-50 … +85 °C (-58 … +185 °F)
(for Neobee: -20 ... + 85 °C (-4 ... +185 °F))
(for high-temperature oil: -10 ... + 85 °C (14 ... 185 °F))
● Degree of protection in
accordance with EN 60 529
IP65, IP68
● Degree of protection in
NEMA 4X
Electromagnetic compatibility
Interference emission and
interference immunity
In accordance with EN 61326 and NAMUR NE 21