SITRANS P310 with HART
A5E35075329-01, 05/2015
37
Rated conditions for differential pressure and flow rate
In conjunction with
dust explosion protection
-20 … +60°C (-4 … +140°F)
Constructional design, gauge pressure
Approx. 1.5 kg (3.3 lb) for aluminum enclosure
•
Stainless steel, mat. no. 1.4404/316L or Hastelloy C4, mat. no. 2.4610
Stainless steel, material no. 1.4404/316L or Hastelloy C276, material no. 2.4819
•
Non-wetted parts materials
Electronics housing
• Low-copper aluminum die casting GD-AlSi 12
• Standard: Polyester-based paint
•
Stainless steel nameplate
•
Process connection Connection shank G
1
/
2
B in accordance with DIN EN 837-1; female thread
1
/
2
-14
NPT; male thread M20 x 1.5 und 1/2-14 NPT
Electrical connection Cable entry through the following glands:
M20 x 1.5 and ½-14 NPT
• Cable diameter: 6 to 12 mm; types of protection "nA" and "ic" (Zone 2): 8 to 12
mm or a suitable cable gland for smaller diameters
Nut torque for cable gland made of
Constructional design, differential pressure and flow rate
Approx. 4.5 kg (9.9 lb) for aluminum enclosure
•
Stainless steel, mat. no. 1.4404/316L, Hastelloy C276
Pressure caps and locking screw
Stainless steel, mat. no. 1.4408 to PN 160
•
Non-wetted parts materials
Electronics housing
•
Low-copper aluminum die casting GD-AlSi 12
• Standard: Polyester-based paint
•
Stainless steel nameplate
•
1
4
-18 NPT with fastening screw thread
7
14
Electrical connection Screw terminals
Cable entry through the following glands:
• M20 x 1.5
Nut torque for cable gland made of