Certificates and approvals
Certificates and approvals
Classification according to Pressure
Equipment Directive (PED 97/23/EC)
•
for gases of Fluid Group 1 and liquids of Fluid Group 1; meets requirements of
Article 3 Para. 3 (good engineering practice)
• only for flow rate:
for gases of Fluid Group 1 and liquids of Fluid Group 1; fulfills the basic safety
requirements as per article 3, Para 1 (appendix 1); classified as category III,
module H conformity evaluation by TÜV Nord
Available soon (for SITRANS P DSIII)
• Intrinsic safety "i"
Designation
II 1/2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb
Permissible ambient temperature -40 … +85 °C (-40 … +185 °F) temperature class T4
-40 … +70 °C (-40 … +158 °F) temperature class T5
-40 … +60 °C (-40 … +140 °F) temperature class T6
Connection To a certified intrinsically safe circuit with the max. values:
U
i
= 30 V, I
i
= 100 mA,
P
i
= 750 mW, R
i
= 300 Ω
Effective inner capacitance
Effective inner inductance L
i
= 0.4 mH
• Flameproof enclosure
Designation
II 1/2 G Ex d IIC T4, T6 Ga/Gb
Permissible ambient temperature -40 … +85 °C (-40 … +185 °F) temperature class T4
-40 … +60 °C (-40 … +140 °F) temperature class T6
Connection To a circuit with the operating values:
• Dust explosion protection for Zone
Designation
II 1 D Ex ta IIIC T120°C Da,
II 1/2 D Ex ta/tb IIIC T120°C Da/Db
Permissible ambient temperature
-40 ... +85 °C (-40 ... +185 °F)
Connection To a certified intrinsically safe circuit with the max. values:
U
i
= 30 V, I
i
= 100 mA,
i
i
Effective inner capacitance
i
Effective inner inductance L
i
= 0.4 mH
•
Dust explosion protection for Zone
22
Designation
II 2 D Ex tb IIIC T120°C Db
Connection To a circuit with the operating values:
H
max
•
Type of protection "n" (Zone 2)