WARNING
Unsuitable cables, cable glands and/or plugs
Risk of e
xplosion in hazardous areas.
Use only cable glands/plugs that comply with the requirements for the relevant type of
protection.
Tighten the cable glands in accordance with the torques speci󹪝ed in Technical data
(Page 79).
Close unused cable inlets for the electrical connections.
When replacing cable glands, only use cable glands of the same type.
After installation, check that the cables are seated 󹪝rmly.
WARNING
Improper power supply
Risk of e
xplosion in hazardous areas as result of incorrect power supply.
Connect the device in accordance with the speci󹪝ed power supply and signal circuits. The
relevant speci󹪝cations can be found in the certi󹪝cates, in Technical data (Page 79) or on
the nameplate.
NOTICE
Ambient temperature too high
Damag
e to cable sheath.
At an ambient temperature ≥ 60 °C (140 °F), use heat-resistant cables suitable for an
ambient temperature at least 20 °C (36 °F) higher.
WARNING
Connecting device in energized state
Risk of e
xplosion in hazardous areas.
Connect devices in hazardous areas only in a de-energized state.
Exceptions:
Devices having the type of protection "Intrinsic safety Ex i" may also be connected in
energized state in hazardous areas.
Exceptions for type of protection "Non-sparking nA/ec" (Zone 2) are regulated in the
relevant certi󹪝cate.