EasyManua.ls Logo

Siemens SIWAREX WL200 Series - Siwarex Wl260 Sp-S Sa

Siemens SIWAREX WL200 Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
9.1 Functional data
SIWAREX WL200
48 Operating Instructions, 07/2016, A5E02199611B-03
Variable
Value
Maximum tightening torque of the fixing screws
1.3 Nm
Cable connection Four-core, shielded
0.4 m
9.1.4
SIWAREX WL260 SP-S SA
Table 9- 4 Technical data SIWAREX WL260 SP-S SA
Variable
Value
Type series
WL260
Designation
SP-S SA
Construction type
Single-point load cell
Possible applications Platform scales,
conveyor scales
Rated load E
max
5; 10; 20; 50; 100; 200 kg
Accuracy class according to OIML R60
C3
1)
Max. scale interval n
LC
3000
Min. scale interval V
min
E
max
/ 7500
Combined error F
comb
± 0.02% C
n
Deviation F
V
± 0.017% C
n
Creep error F
cr
30 min
0.02% C
n
Temperature coefficient
Characteristic value T
Kc
Zero signal T
Ko
0.014% C
n
/ 10 K
0.017% C
n
/ 10 K
Min. initial loading E
min
0 kg
Maximum working load L
u
150% E
max
Break load L
d
300% E
max
Maximum lateral load L
lq
100% E
max
Rated measuring path h
n
at E
max
0.27 ± 0.05 mm
Recommended supply voltage 5 to 12 V DC
Rated characteristic value C
Rated
2.0 ± 0.2 mV/V
Tolerance of zero signal D
o
< ± 1.0% C
n
Input resistance R
i
383 ± 4 Ω
Output resistance R
o
351 ± 2 Ω
Insulation resistance R
is
5000 MΩ at V DC
Rated temperature range B
tn
- 10 ... + 40 °C
Operating temperature range B
tu
- 35 ... + 65 °C
Storage temperature range B
ts
- 40 ... + 70 °C
Sensor material
Stainless steel
Degree of protection according to EN 60 529
IP67

Table of Contents

Related product manuals