EasyManua.ls Logo

Siemens SIWAREX WL200 Series - Siwarex Wl260 Sp-S Sc

Siemens SIWAREX WL200 Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
9.1 Functional data
SIWAREX WL200
50 Operating Instructions, 07/2016, A5E02199611B-03
Variable
Value
Sensor material
Stainless steel, mat. no. 1.4542
Degree of protection according to EN 60 529
IP68
Cable connection Six-core, shielded PU cable
6 m
Maximum tightening torque of the fixing screws
10 Nm
9.1.6
SIWAREX WL260 SP-S SC
Table 9- 6 Technical data SIWAREX WL260 SP-S SC
Variable
Value
Type series
WL260
Designation
SP-S SC
Construction type
Single-point load cell
Possible applications
Single-point scales, conveyor scales
Rated load E
max
10, 20, 50, 100, 200, 300,
400, 500 kg
10, 20, 50 kg
Accuracy class according to
OIML R60
C3 C4
Max. scale interval n
LC
3000
4000
Min. scale interval V
min
E
max
/ 10000
1)
E
max
/ 40000
Combined error F
comb
± 0.02% C
n
≤ ± 0.014% Cn
Deviation F
V
± 0.02% C
n
Creep error F
cr
30 min
≤ ± 0.0245 %
≤ ± 0.0184 %
Temperature coefficient
Characteristic value T
Kc
Zero signal T
Ko
± 0.0100 %
≤ ± 0.0140 %
≤ ± 0.0080 %
≤ ± 0.0035 %
Min. initial loading E
min
0 kg 0 kg
Maximum working load L
u
150% E
max
150% E
max
Break load L
d
300% E
max
300% E
max
Maximum lateral load L
lq
100% E
max
100% E
max
Rated measuring path h
n
at E
max
=
50, 100, 250, 500 kg
0.19 mm
Recommended supply voltage
5 to 12 V DC
Maximum supply voltage
18 V DC
Rated characteristic value C
Rated
2.0 ± 0.2 mV/V
Tolerance of zero signal D
o
< ± 2.0% C
n
Input resistance R
i
for E
max
10, 20, 50
380 ± 15 Ω
for E
max
100, 200, 300, 400, 500
350 ± 3.5 Ω

Table of Contents