EasyManua.ls Logo

Siemens TC35i - Page 58

Siemens TC35i
439 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC35i AT Command Set
2.14 AT^SCFG
s
m
obil
e
TC35i_ATC_V02.07 Page 58 of 439 1/30/04
Confidential / Released
EXAMPLE 3
Switch off the TC35i after three minutes without restart.
For details regarding software controlled power down refer to
AT+CFUN and AT^SMSO.
After three minutes:
AT^SCFG="AutoExec",1,1,3,0,"AT^SMSO","000:03:00"
...
OK
^SCFG:"AutoExec",0,1,3,0,"AT^SMSO"
OK
"AT^SMSO" command entry confirmation
^SHUTDOWN
"AT^SMSO" command response