TC35i AT Command Set
18.5 Factory Default Settings Restorable with AT&F
s
m
obil
e
TC35i_ATC_V02.07 Page 429 of 439 1/30/04
Confidential / Released
18.5 Factory Default Settings Restorable with AT&F
Table 18.6: Factory Default Settings Restorable with AT&F
AT Command Factory Defaults
Configuration Commands
ATQ <n>=0
ATV <value>=1
ATX <value>=4
AT\V <value>=1
AT+CFUN <fun>=1
AT+CMEE <n>=0
AT+CSCS <chset>="GSM"
AT^SM20 <CallMode>=1, <CmgwMode>=1
Status Control Commands
AT+CMER <mode>=0, <keyp>=0, <disp>=0, <ind>=0,
<bfr>=0
ATS18 <n>=0
Serial Interface Control Commands
AT\Q <n>=0
AT&C <value>=1
AT&D <value>=2
AT%D <mode>=0, <dialType>=" "
AT&S <value>=0
ATE <value>=1
AT+ILRR <value>=0
AT^STPB <n>=0
Call related Commands
ATD><mem><n> <mem>="SM"
ATS0 <n>=000
ATS6 <n>=000
ATS7 <n>=060
ATS10 <n>=002
AT+CBST <speed>=7, <name>=0, <ce>=1
AT+CRLP <iws>=61, <mws>=61, <T1>=78, <N2>=6
AT+CR <mode>=0
AT+CRC <mode>=0