2. MACHINE SAFETY
The machine is tted with 3 safety functions.
• MainMachineDoor
• CutterSafetyFunction
• EmergencyStops
All of the safety functions are motored by the Siemens S7-1214FC Safety PLC. This
handles most of the machines logic and safety functions.
By pressing the Emergency Stop or opening the main machine door, will bring the
machine to a controlled stop and remove all torque and energy from motors and
actuators.
The following screens will appear if the Emergency Stop safety function is called
upon.
Once released and the circuit is complete, it can be reset by pressing the blue safety
circuit reset button, causing the screen to return to the main control screen.
Opening the main door of the machine will act in the same way as pressing the
Emergency Stop.
The Emergency Stop will always display if called upon, even if other safety functions
are active at the same time.
If the main door is opened, the following screen will be displayed instead: