Adjusting minimum gas pressure:
press the button
r
twice, the message
"P00"
will appear on
the display
press the buttons
>
or
<
until the pressure value indicated in
the table appears on the pressure gauge
once the value indicated in the table has been reached, press
the button
y
for approximately 2 seconds to confirm the
value which will then flash once
press and hold down the buttons
>
and
y
at the same time
for approximately 6 seconds until the water delivery tempera-
ture appears on the display and the boiler shuts down
close the valves which were opened previously
disconnect the pressure gauges, carefully close the pressure
points (6) and (7), put the control panel back to the original
position and refit the front panel (2).
6
7
Fig. 45
Gas supply pressure
Type of gas G20 G30 G31
Pressure
(mbar)
20 28-30 37
Installation with SPLIT PIPE SYSTEM smoke outlet
Model
Heat Out
-
put
Pr
es
sure at nozzles (mbar)
G20 G30 G31
Brava Slim
25 BF
Max 12,2 - 12,6 27,8 - 28,2 35,8 - 36,2
min 0,8 - 1,1 2,2 - 2,5 2,8 - 3,1
Brava Slim
30 BF
Max 12,5 - 12,9 27,8 - 28,2 35,8 - 36,2
min 0,6 - 0,9 2,6 - 2,9 3,4 - 3,7
Installation with CONCENTRIC smoke outlet
Model
Heat Out
-
put
Pr
es
sure at nozzles (mbar)
G20 G30 G31
Brava Slim
30 BF
Max 12,9 - 13,3 27,8 - 28,2 35,8 - 36,2
min 1,4 - 1,7 3,8 - 4,1 4,8 - 5,1
3.9 Domestic hot water comfort function (pre-
heating)
Brava Slim BF
models have a "domestic hot water comfort" func-
tion which ensures the best performance in terms of domestic
hot water
, reducing the time necessary for the hot water to be-
come available and ensuring that the temperature is stable.
T
o activ
ate the function:
select parameter
"PAR 22"
(see "Parameter setting and dis-
play") and set it to
a 1
exit parameter settings and press button
>
for approximately
5 seconds until the symbol
r
appears on the display and be-
gins to flash indicating that the function has been activated.
To deactivate the function:
press button
>
again for approximately 5 seconds until the
symbols
r
and
R
appear on the display and begin to flash
indicating that the function has been deactivated.