OWNER’S MANUAL
Submersible Sump Pumps
NOTICE D’UTILISATION
Pompes submersibles
pour puisard
MANUAL DEL USUARIO
Bombas sumergibles
para sumideros y efluentes
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 800-468-7867 /
800-546-7867
English ...................... Pages 2-7
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
(800) 468-7867 /
(800) 546-7867
Français ................ Pages 8-12
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 800-468-7867 /
800-546-7867
Español ............... Paginas 13-19
©2012 SIM846 (07/16/12)
1569 0195
1572 0195 Vert GEN
2943, 2945 2956, 2958
293 Wright Street, Delavan, WI 53115
Phone: 800-468-7867
Fax: 800-390-5351
www.simerpump.com

Questions and Answers

  • C
    Chad PerezSep 23, 2025
    What to do if Simer Water Pump starts and stops too often?
    • B
      bcampbellSep 23, 2025
      If your Simer Water Pump starts and stops too often, the issue might be: * Backflow of water from piping: Install or replace the check-valve. * A faulty float switch: Replace the float switch.
  • C
    Cynthia WoodsAug 25, 2025
    What to do if Simer 2943 has no voltage at fuse box?
    • J
      joseph76Aug 25, 2025
      If there's no voltage at the fuse box for your Simer Water Pump, the suggested solution is to replace any blown fuses.
  • J
    Jennifer BanksAug 25, 2025
    What to do if Simer Water Pump is stuck or binding?
    • R
      Roberto BridgesAug 26, 2025
      If your Simer Water Pump is stuck or binding: * First, perform all possible above-ground checks. * If necessary, pull the pump. * If the pump is locked, replace it. * Clean the well of all sand or lime before reinstalling the pump.
  • T
    Thomas MccormickAug 27, 2025
    What to do if Simer 2943 Water Pump has wrong size fuse?
    • J
      Justin LewisAug 27, 2025
      If your Simer Water Pump has the wrong size fuse or wrong size time delay fuse, install the correct fuse or time delay fuse.
  • E
    Eric CrawfordAug 27, 2025
    What to do if Simer 2943 starting capacitor is defective?
    • K
      Katherine PetersonAug 27, 2025
      If the starting capacitor in your Simer Water Pump is defective or blown, replace it.
  • B
    Bryan CooperSep 13, 2025
    What to do if Simer Water Pump has no voltage at control box?
    • R
      robertsgregorySep 14, 2025
      To address a situation where there is no voltage at the control box of your Simer Water Pump, rewire the supply to the control box.
  • H
    Hannah RhodesSep 12, 2025
    What to do if Simer 2943 has wrong voltage control box?
    • K
      Kelly WrightSep 12, 2025
      If the control box for your Simer Water Pump has the wrong voltage or horsepower rating, replace the control box if the numbers do not match.
  • K
    kristenchapmanSep 12, 2025
    What to do if Simer 2943 has air volume control not working?
    • K
      kelly42Sep 12, 2025
      If the air volume control is not working in your Simer Water Pump (standard tanks only), replace the control if necessary.
  • J
    Julie SmithSep 4, 2025
    How to fix Simer Water Pump with broken wire in control box?
    • A
      Alyssa GordonSep 4, 2025
      To fix a broken wire in the control box of your Simer Water Pump, disconnect the power and then repair or replace the faulty wire.
  • D
    Daniel EdwardsSep 2, 2025
    What to do if Simer Water Pump has no voltage at pressure switch?
    • L
      Lisa ChristianSep 2, 2025
      If there's no voltage at the pressure switch for your Simer Water Pump, replace the faulty pressure switch.