©2005 1000000171 (Rev. 7/26/06)
OWNER’S MANUAL
Convertible Deep Well Jet Pumps
and Tank System
NOTICE D’UTILISATION
Pompes à éjecteur
transformables pour puits
profond et système de réservoir
sous pression
MANUAL DEL USUARIO
Bombas de chorro
convertibles para pozos
profundos y Sistema de Tanque
Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 1-800-365-6832
English . . . . . . . . . . . . . . Pages 2-14
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français . . . . . . . . . . . Pages 15-27
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español . . . . . . . . . . .Paginas 28-40
4025 0801
Mod. Nos. 2805E-01, 2806E-01,
2810E-01, 2815E-01
293 Wright St., Delavan, WI 53115
Phone:
1-800-468-7867
1-800-546-7867
Fax:
1-800-390-5351
Web Site:
http://www.simerpump.com

Questions and Answers

  • C
    Cory PhillipsAug 12, 2025
    How to fix Simer Water Pump motor that will not run?
    • D
      Donald TurnerAug 12, 2025
      If your Simer Water Pump motor won't run, start by checking if the disconnect switch is on. If not, turn it on. Next, inspect the fuse and circuit breaker; replace the fuse or reset the circuit breaker if needed. If the starting switch is defective, disconnect the power and replace it. Refer to the wiring instructions to check and tighten any loose, disconnected, or incorrectly wired wires at the motor, after disconnecting power. Lastly, if the pressure switch contacts are dirty, disconnect the power and file them with an emery board or nail file.
  • E
    Eric GrahamAug 17, 2025
    Why does my Simer Water Pump motor run hot and the overload kicks off?
    • J
      Jacob GonzalezAug 17, 2025
      If your Simer Water Pump motor runs hot and the overload kicks off, it could be due to a few reasons. The motor might be wired incorrectly, so refer to the wiring instructions. The voltage might be too low, so check with the power company and consider installing heavier wiring if the wire size is too small. Lastly, the pump might be cycling too frequently; refer to the section on too frequent cycling.
  • J
    John Pearson MDAug 22, 2025
    Why does my Simer Water Pump deliver water but not to full capacity?
    • S
      Samuel KingAug 22, 2025
      If your Simer Water Pump isn't delivering water to its full capacity, it could be due to a few reasons. If you have a deep well, the water level might be lower than estimated; in this case, replace the nozzle and venturi with the correct combination for the well and lower the ejector to the correct level. If steel piping is used, it might be corroded or limed, causing excess friction; replace it with plastic pipe where possible, or with new steel pipe. Finally, the piping might be too small in size, so use larger piping.
  • T
    Teresa RobinsonAug 27, 2025
    What causes air spurts from faucets with my Simer Water Pump?
    • L
      Logan RichardsonAug 27, 2025
      Air spurts from faucets connected to your Simer Water Pump can occur for several reasons. The pump might be picking up prime; when this happens, all air will eventually be ejected. There could be a leak in the suction side of the pump, causing the suction pipe to suck air; check the joints for leaks. The well itself might be gaseous; consult the factory about installing a sleeve in the well. Finally, intermittent over-pumping of the well (drawing water down below the foot valve) can cause this issue; lower the foot valve if possible, or restrict pump discharge.
  • M
    Melanie Mckay DDSNov 2, 2025
    Why does my Simer Water Pump deliver water but not shut off or cycle too frequently?
    • S
      Stanley MedinaNov 2, 2025
      Your Simer Water Pump might not be shutting off or is cycling too frequently due to several reasons. It could be that the pressure switch is out of adjustment or the contacts are welded together, in which case you should disconnect the power and adjust or replace the pressure switch. Other potential causes include open faucets (close them), a clogged venturi, nozzle, or impeller (clean them), a water level in a deep well that's lower than estimated (replace the nozzle and venturi with the correct combination for the well), a waterlogged standard pressure tank with no air cushion (drain the tank to the air volume control port and check the AVC for defects), leaking pipes (check connections for air leaks), leaking foot valves (replace the foot valve), or an air charge that is too low in the ...
  • J
    Jillian BrooksNov 7, 2025
    What to do if my Simer Water Pump motor runs but no water is delivered?
    • T
      Thomas WilsonNov 7, 2025
      If your Simer Water Pump motor runs but isn't delivering water, several issues could be the cause. If it's a new installation, the pump might not have picked up prime, so re-prime it according to the instructions. Check for air leaks in all connections on the suction line, AVC, and ejector. A leaking foot valve or check valve should be replaced. If the pump has lost prime, inspect all connections on the suction line and shaft seal. Ensure the water level isn't below the suction pipe inlet; lower the suction line into the water and re-prime. Also, check if the foot valve, strainer, ejector, or impeller are plugged and clean them if necessary. Replace any check valves or foot valves that are stuck shut. Thaw any frozen pipes. Ensure the foot valve and/or strainer are not buried in sand or mu...

Summary

Safety

Electrical Safety

Details electrical hazards like shock, burn, or death, and capacitor voltage warnings.

General Safety

Covers burn hazards, freezing, proper usage, inspection, safety glasses, and work area cleanliness.

Warranty Information

Replacing an Existing Pump

Shallow Well Installation

Instructions for replacing an existing pump in a shallow well system.

Deep Well Installation

Instructions for replacing an existing pump in a deep well system.

New Shallow Well Installation

Well Point Installation

Steps for installing a pump using a well point in a shallow well system.

Cased Well Installation (2 or Larger)

Steps for installing a pump in a cased well with 2-inch or larger casing.

Installation for Surface Water

Steps for installing a pump for surface water sources in a shallow well system.

New Deep Well Installation

4 or Larger Well Installation

Steps for installing a pump in a deep well with 4-inch or larger casing.

2 Well Installation

Steps for installing a pump in a deep well with 2-inch casing.

Pre-Charge Tank Connection

Instructions for connecting a pre-charged tank to the pump system.

Standard Tank Connection

Instructions for connecting a standard tank to the pump system.

Electrical

Motor Switch Settings

Details on dual-voltage motor settings, voltage selection, and wiring precautions.

Wiring Connections

Procedure for connecting pump wiring, including grounding and wire size recommendations.

Preparing to Start the Pump - Deep Well

Preparing to Start the Pump - Shallow Well

Troubleshooting

Repair Parts

Simer 2805E-01 Specifications

General IconGeneral
Model2805E-01
CategoryWater Pump
Maximum Flow Rate7000 l/h
Maximum Delivery Height6 m
Max Head6 m
Motor Power300 W
Power Consumption300 W