X2 Screws
Door Monitoring components (conventional fastening system)
A Installation tool for cable
B Fastening screw sensor
C Bolt sensor
D Installation tool for bolt sensor
E Anti-twist mechanism
7.6.4.2 Step 0: Preparing drill holes
IMPORTANT
Please remove the lock from the door before drilling to prevent it from be-
coming damaged! The lock can be reinstalled in the door once you have
completed drilling.
1. Align drilling template precisely.
9 The cut for the spindle must be positioned exactly over the retainer
opening in the door lock.
9 The template must be positioned completely parallel to the door
edge. The dimension lines act as a reference.
2. Use a suitable pen or pencil to mark the two drill holes.
3. Place drilling template back on again to check the marks are correct.
4. Drill top hole with a suitable 8mm drill bit.
5. Drill lower hole with a suitable 13 mm drill bit.
It is recommended to pre-
drill the hole with a 8mm bit first.
7.6.4.3 Step 1: Installing the fastening screw sensor
IMPORTANT
The fastening screw sensor may not be in locked final position during in-
stallation. The fastening screw sensor must be in the displayed "INSTALL-
ATION" position; otherwise ("LOCKED") the outer ring must be pushed
back carefully so that the spring mechanism is tensioned.
SmartHandle (Manual)
7. Installation (manual)
69 / 136