16. Use the four screws (11) to join the inner side adapter plate (10) with the
outer fitting (4) from the inside, ensuring that the fitting can still move
freely.
17. Position the fitting parallel to the door leaf; otherwise, you may not be
able to mount the inside fitting (12). If this is the case, you will need to
re-align the fitting.
18. Fasten the screws (11) until the adapter plate (10) lies flat against the
door.
19. The inside fitting (12) is mounted onto the inner surface of the door.
Push the inner fitting spindle through the mortise lock (9) retainer slot
and push the inner fitting (12) until it is flush with the door. In doing so,
push the 2-pole cable through the cylinder opening in the mortise lock
and ensure that it does not get caught.
20.Press outer and inside fittings together, so that they are both flush
against the door.
21. Press the electronics module cover lid in the inside fitting carefully out
of its bracket and fold back horizontally. Make sure that the electronics
are not subject to mechanical load and are not damaged in any other
way.
22. Carefully remove the lower battery (14) from the holder. Use clean
gloves free of fat or grease to handle batteries.
23. Use the two screws (13) to fasten the inside fitting (12) to the adapter
plate (10), using about 5-7 Nm of force.
24.Insert the lower battery (14) with the positive terminals facing away
from the door into the brackets; in doing so, insert the batteries under
the black retaining collar first. Use clean gloves free of fat or grease to
handle batteries.
25. Carefully lock the electronics cover lid back into place.
26.Connect the 2-pole cable from the outer fitting to the 2-pole cable from
the inside fitting. This cable can only be inserted in one direction. Do not
pull on the cables while doing so; just carefully secure the plug-in con-
nection into position. Optional: Connect the two-pole cable of the addi-
tional electronic module on the outer side with the respective cable of
the inside fitting.
27. The 2-pole cable from the outer fitting may hang freely; when mounting
the outside cover (2) onto the fitting, ensure that the cables do not get
caught or broken. Do not pull on the cables. The second cable is option-
ally used to connect the LockNode circuit board.
SmartHandle (Manual)
7. Installation (manual)
91 / 136