EasyManuals Logo

Simplicity SYNERGY X9.5 User Manual

Simplicity SYNERGY X9.5
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
071807 III. General Troubleshooting
24
D. Excessive Vibration
1. Check the direct air fan for damage. Replace if necessary. (See II. Maintenance Procedures, J. Replacing the Direct Air Motor Fan)
2. The agitator/brushroll may be out of balance.
3. To test the agitator/brushroll for balance:
Models .4 and older:
1. Remove the agitator/brushroll and run the direct air motor.
2. If vibration stops with the agitator/brushroll removed, replace the agitator/brushroll and retest.
Models .5 and newer:
1. Remove the nozzle cover and install the hall sensor test plug. (If test plug is not installed, the direct air motor will only run 2 to
3 seconds and then shut off.)
2. Remove the agitator/brushroll and run the direct air motor.
3. If vibration stops with the agitator/brushroll removed, replace the agitator/brushroll and retest.
E. Agitator/brushroll Does Not Rotate
1. Check the condition of the belt. Replace if necessary.
2. Check the agitator/brushroll for excessive hair build-up. Clean agitator/brushroll if necessary.
Also see III. General Troubleshooting, B. Direct Air Motor Will Not Run

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplicity SYNERGY X9.5 and is the answer not in the manual?

Simplicity SYNERGY X9.5 Specifications

General IconGeneral
BrandSimplicity
ModelSYNERGY X9.5
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals