CP34/44/54 Troubleshooting, Service and Specifications Chapter 9-3
9.4 Specifications
General data
Power supply: 12 and 24 V DC (10-32 V DC max) 30 watts
Power cable: 2 m incl. fuse (153-5000-006)
Dimensions: CP34: H:220 mm (8.7”) L:220 mm (8.7”) D:112 mm (4.5)
CP44: H:220 mm (8.7”) W:365 mm (14.6”) D:75 mm (3”)
CP54: H:330 mm (13”) W:460 mm (18.1”) D:95 mm (3.7”)
Weight:
CP34: 3.2 kg (7 lbs), CP44: 3.7 kg (8.1 lbs), CP54: 6.6 kg (14.5 lbs)
Environment: 0° to +50°C, waterproof USC 46 CFR and IP55
Housing: Casted aluminum back, polycarbonate front
Display: TFT/ATFT color, power backlight, 640x480 pixels,
Interfaces: XX34: 1 port in/out NMEA 0183
1 port SimNet/NMEA2000
XX44/54: 2 ports in/out NMEA 0183 (incl.SimNet/
NMEA2000 via AT44 Active Tee)
PC up/download WPL and RTE
- alarm: Alarm relay (contact closure), (CP44/54)
Signal output 5 V 50 mA (CP34)
- log out: 200 pulses/nm (5 Volt pulses), (CP44/54)
Main fuse: T6.3A slow (5x20 mm)
SimNet control
Maximum number of products connected in a network:.....................50 units
Maximum cable length (excl. 30 m wind transducer cable):.......120 m (400)
Bit rate of the bus:................................................................... 250 kbit/second
Maximum DC current through a single SimNet plug: ................................5A
SimNet power supply:...............................................................10.8 - 15 VDC
Maximum drop cable length:.............................................................6 m (20’)
Maximum total length of all drop cables ......................................60 m (200’)
Environmental protection: Cable and plug/connector system:.................IP66
Temperature:...................................................................... max. 70°C (158°F)
GPS section
Receiver type: 14 channel parallel, C/A code, 8 state Kalman filter
Accuracy: Position (DGPS): 2-5 m RMS
Position (SDGPS): 3-7 m RMS
Position (GPS): 8 m RMS
Speed: 0.1 kn
Course: 1°
Speed filter: 10 settings
Update rate: 1 second interval, typical