| 37
System conguration | MX610/MX612 Operator and Installation manual
REMOTE PORT3
PORT1 PORT2
PORT4 SUPPLY
+ -
TERMINATION
SIMNET
SIMNET
BLU
BRN
ORG
GRN
YEL
WHT
RED
BLK
MX521A
MX521B
MX61xJB PCB Terminals
ANTENNA CABLE
GRY
PRPL
RX+
RX-
TX+
TX-
NMEA 0183 PORT
CONNECTOR TERMINALS
+12/24 VDC
NEG
Ext. RTCM
@4800 Baud
-
+
Mixed Mode
This feature allows position calculation using all available satellites
in view whether they have differential correction data or not. In
areas where beacon differential signal from land-based station or
SBAS is marginal and only partial satellite correction is available, it
may be useful to use the MIXED mode selection.
Reset Procedures
In order to access the RESET functionality, the following software
versions have to be in place:
MX61x CDU - s/w version 1.0.42.235 (or newer),
MX61xJB junction box - s/w version 1100 100121 (or newer)
How to RESET the Junction Box: (MX610JB & MX612JB)
1. Press the MENU key.
2. Scroll to Tools & Settings, press ENT.
3. Scroll to NETWORK, press ENT.
4. Scroll to “NMEA Over MX61xJB”, press ENT.
5. Scroll to either “Restore to Default” or “Power Reset”, press ENT.
6. Press the CLR key repeatedly or press any hot keys to exit.
MX612 with 12 Ports MX610 with 4 Ports
Where:
Power Reset - cycles the power to the junction box.
Restore to default - restores baud rate of ports as per the table below.