Wiring | MX610/MX612 Operator and Installation Manual
Procedure for printer output setting:
1. Press the MENU key.
2. Scroll to Tools and Settings, press ENT.
3. Scroll to Device List, press ENT.
4. Select MXJB NMEA1 (or Port 1 or any port used to connect to a printer), press ENT.
5. Scroll to Baud Rate, press ENT.
6. Select the baud rate to match what the printer needs.
7. Scroll to Printer output, press ENT.
8. Select the printing time (typically 1/hr), press ENT.
9. Select Yes, press ENT.
10. Highlight the Close button, press ENT.
11. Press CLR or any hot key to exit.
T
T
12/24V DC
MX61xJB
12/24V DC
Where:
N2K Backbone
Drop line
NMEA 0183 line
MX610/MX612
MX521
MX521A
MX521B
Ports 3&4
Thermal
Printer
RS-232 to RS-422
Converter
P1
RX+ RX- TX+ TX-
GND
+12V
RD(B)
RD(A)
TD(A)
TD(B)
B&B Elect.
Model: 422LP9TB
RS232-RS422
Converter
P1 (or any JB Port)
9-Pin dB
connector
To Printer
(25-Pin dB
Connector)