VisualinspectionoftheOperatingPanel
AvisualinspectionoftheOperatingPanelisrequiredtoverifythattheunithasnotbeen
physicallydamagedduringtheinstallation..
Prerequisites
TheST90isinstalledasspeciedintheST90Installationmanual.TheST90isturned
off.Youneedthefollowingequipment:
Multimeter
Procedure
1Makesurethattheunit’sserialnumberhasbeenrecordedinthelistofhardware
items.
2Makesurethatthephysicalinstallationoftheunithasbeencompleted.
aIftheunitisinstalledinsidearackorinaclosedcompartment,makesurethat
ampleventilationisprovidedtoavoidoverheating.
bMakesurethatamplespaceisprovidedaroundtheunittoallowfor
maintenanceandreplacementofparts.
cMakesurethatthebolts,screwsorstudsholdingtheunitareofthecorrectsize.
dMakesurethatthecorrectatandshake-proofwashershavebeenused.
eMakesurethatallnutshavebeentightenedproperly.
3MakesurethattheOperatingPanelisinstalledinthecorrectlocation,andthatitis
suitablyorientedforeasymaintenanceandreplacementofparts.
4Makesurethattheunitisnotphysicallydamaged,andthatthepaint-workisclean
withoutdentsorscratches.
Thephysicalhandlingoftheunitduringtheinstallationmayhavecausedsome
minorscratchestothepaint-work.Thiscanbeaccepted.However,ifrough
handlinghascausedseriousdamagetotheunit,thismustberecordedwithawritten
statementandnecessaryphotos,sothatcorrectiveactionscanbemade.
5Makesurethattheunitisrmlyconnectedtoship'sground.
aMakesurethattheunitissecurelyconnectedtotheship'sgroundwithan
earthingstrap.Thestrapmustbeinadditiontoanyincidentalelectricalcontact
madebythemountinglugsontheunit.
bUseastandardmultimetertocheckthattheresistancebetweentheunitandthe
ship'sgroundisapproximately0(zero)Ω.
6Makesurethatcableinstallationhasbeencompleted.
aMakesurethatallcablesleadingtoandfromtheunithavebeenproperly
mountedandsecured.
bMakesurethatenoughslackhasbeenprovidedoneachcabletoallowfor
maintenanceandreplacement.
Visualinspection

Table of Contents

Other manuals for Simrad ST90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad ST90 and is the answer not in the manual?

Simrad ST90 Specifications

General IconGeneral
BrandSimrad
ModelST90
CategorySonar
LanguageEnglish

Related product manuals