8Ifpossible,useanotherinstrumenttoverifythattheinformationprovidedbythe
ST90iscorrect.
9Fillintheresulttables.
Result
SensorSourcesensor
DatagramPortBaudrate
Position
Speed
Distance
Heading
XOffsetYOffsetZOffset
Requirements
Results
Positiondataisprovided.
Speeddataisprovided.
Distancedataisprovided.
Headingdataisprovided.
Therelevantcommunicationparametersarerecorded.
Dateandsignature:
Verifyingthecommunicationwithspeedlog
Inordertooperatecorrectly,theST90requiresinputfromaspeedlog.Thevesselspeed
isshownonthetopbarifyouhaveenabledthisintheDisplayOptionsdialogbox.The
communicationwiththesensoristested.
Prerequisites
TheST90isinstalledasspeciedintheST90Installationmanual.
ThesensorisconnectedtoacommunicationportontheST90.Thesensorison
andinnormaloperation.
Theinterfaceportissetupwiththecorrectcommunicationparameters.
YouarefamiliarwithNMEAandotherrelevantdatagramformats.
Youknowhowtosetuptheparametersforserialandlocalareanetwork(LAN)
communication.
Thevesselisberthedoratsea.
SimradST90HarbourAcceptanceTest