60
442729/A
4AddasingleProcessorUnittotheOperatingPanelconguration.
aSelectSonarPCsCongurationonthetopmenutoopenthepage.
bTypeorcopytheIPaddressintotherelevantbox.
cTypeorcopytheMACaddressintotherelevantbox.
dSelectADDSonarPC.
eObservethatyourProcessorUnitisaddedtothelist.
fClosethewebbrowser.
5MakesurethattheOperatingPanelisfunctional.
aMakesurethattheblueindicatorislit,andcheckthatyoucanmovethe
cursoronthescreen.
bOntheProcessorUnitdesktop,double-clicktheST90icontostarttheprogram.
WaituntiltheST90operatesnormally.
cPressandholdPowerdepressedfourminimumfoursecondstoturnoffthe
OperatingPanel.
ObservethattheTransceiverOn/Offdialogboxopensautomatically.
MakesurethattheST90isturnedoff.
dTurnontheST90withthePowerbuttonontheOperatingPanel.
eMakesurethatyoucancontrolthecursor,andthatyoucanmakeselectionsin
themenusystem.
fPressand/orturnselectedbuttons,andmakesurethatthecorresponding
functionisactivatedintheuserinterface.
SimradST90HarbourAcceptanceTest