GD1 Page 44 of 76 850-816926-EN R06
Loose wire in Junction
Box
Check terminals 3 6. Unscrew each wire,
both internal and external wiring to the
terminals, and ensure wires are properly
connected to the terminals.
No Ethernet cable
connection
Fault on cable
Check cable.
Device not set up to
connect to fixed IP
address
Configure laptop network settings to
connect using static IP.
Fault in detector
Contact Simtronics.
Fluctuating H
2
S
level
Noisy signal
Tune alignment as described in section 0.
Interfering detector
See section 6.3.
Other error
Check error code in
the Web Service or by
HART®.
See section 0 for a description and
suggestion on how to solve the issue.
Note! After solving an issue the Error code
might still be displayed for some time.
Absolute
transmission not
as high as
expected during
alignment
Dirty optics
Clean optics
Alignment of TX not
optimum
Perform tuning of TX as described in
section 3.3.
Alignment of RX not
optimum
Perform tuning of RX with the same
method as for TX described in section 3.3.
Laser beam
obstructed by an
object
Move the obstructing object or the GD1.